Alphenix

Next-generation of Interventional Systems.

Alphenix

Next-generation of Interventional Systems.


Interventional Neurology

The major driving factor for Adult Interventional Neuro-Radiology is a rapidly aging US population. The rising patient pool for ischemic and hemorrhagic stroke and increasing demand for minimally invasive surgical procedures will ensure growth in this segment for years ahead.

Alphenix Biplane

System Options

Flexible Configurations to Address Your Clinical Needs

Developed in collaboration with leading clinicians, Alphenix offers a range of C-arm positioners designed to offer unprecedented access to your patient.

Alphenix Biplane

WorkRite

Navigate with confidence and accuracy

Improved DSA and 2D roadmap with real-time auto pixel shift to automatically correct the position of the mask image due to body motion. Alpha CT can be used to obtain CT-like 3D imaging data from the C-arm. Superimpose this 3D data or prior CT/MR data with the live fluoro display to provide additional views of the vascular anatomy to aid clinicians during interventional procedures. Comprehensive planning tools, such as cerebral aneurysm analysis allow for quick and intuitive analysis prior to treatment.

Realtime Auto Pixel Shift

ImagingRite

See and deploy complex devices with confidence

Alphenix’s unique hi-def imaging mode* allows you to effortlessly zoom up to 1.5” in resolution without losing image quality. Alphenix's improved imaging chain, including Illuvis noise reduction technology, provides clean, sharp, defined images during device placement or embolization procedures with enhanced visualization of the surrounding vessels and devices.

*Available as an option only

Hi-Def Imaging Mode

Hi-Def: PED (Φ5mm, L20mm)

ImagingRite

Enhanced visualization during interventional procedures

An improved imaging chain with new hardware and software technologies provide you with fast and assured visualization.

Clinical Example

New High-Definition Detector

Clinical Examples

Aneurysm Stenting

Aneurysm Stenting: Frontal

Frontal (6" Standard FOV)

Aneurysm Stenting: Lateral

Lateral (1.5" Hi-Def Zoom)

Carotid Stenting

Carotid Stenting: Frontal

Frontal (3" Hi-Def Zoom)

Carotid Stenting: Lateral

Lateral (8" Standard FOV)

DoseRite

Comprehensive dose management

DoseRite technologies provide a comprehensive dose management suite of tools designed to help you minimize patient X-ray exposure while maintaining optimum image quality, enabling you to prioritize safe operating conditions for patients and clinical staff.

Dose Management

Interventional Neurology

Toolkit

The major driving factor for Adult Interventional Neurology is a rapidly aging US population. The rising patient pool for ischemic and hemorrhagic stroke and increasing demand for minimally invasive surgical procedures will ensure growth in this segment for years ahead.

3D Angio

Fast and Intuitive Workflow

3D rotational speed up to 50 deg/sec

3D Roadmap

Turn 3D Acquisitions into live Fluoro roadmaps

3D image display changes according to the system conditions such as the C-arm angle, SID, field size, tabletop height, and tabletop panning.

3D Roadmap

3D Roadmap

Alpha CT

Enhanced visualization

To supplement 3D imaging, CT-like Imaging is available to support visualization of anatomy or pathology during interventional procedures.

Alpha CT

  • Head
  • Neck
  • Body
  • Device
  • Vessel
  • MAR
Alpha CT

Cerebral Artery Analysis (CAA)

This application is intended to facilitate the extraction and segmentation of user identified aneurysms on the cerebral arteries from cerebral angiography data, allowing morphological characteristics to be assessed.

Cerebral Artery Analysis (CAA)

Cerebral Artery Analysis

Instant Roadmap

Auto Peak Contrast Detection

Automatic image adjustment during fluoro.

Instant Roadmap

Instant Roadmap

Multi-Modality Fusion

Enhanced visualization during interventional procedures.

Canon Medical's roadmap function enables 3D CT or MR Volume data to be superimposed on the live fluoro display. This feature provides additional views of the vascular anatomy to aid clinicians during interventional procedures.

Multi-Modality Fusion

Needle Guidance

CT or XA Datasets

Needle guidance function enables positioning of the C-arm to the optimum viewing position and display of a puncture guide line for assistance.

Needle Guidance

Needle Guidance

Parametric Imaging¹

  • Video playback with Color Coded Circulation
  • Displays an entire image sequence as a single composite image
  • Color coded in order to characterize contrast media dynamics and allow easier visual evaluation of patients

Parametric parameters include:

  • Time To Peak (TTP)
  • Time To Peak Alpha (TTPα)
  • Peak Height (PH)
  • Area Under Curve (AUC)
  • Time To Arrival (TTA)
  • Time To Arrival Alpha (TTAα)
  • Mean Transit Time (MTT)

¹Parametric Imaging software is not intended for stand-alone use or diagnosis.

Parametric Imaging